Intercom Systems - FAQ's
Q/ what system can I use for Communications between Operating Theatre and Recovery room?
Q/ what is a Speech Channel?
Q/ I have a CCTV camera system and need audio communication to the camera location?
Q/ We need Control of an external door, how can we remotely give access?
Q/ What is a clean room intercom station?
Q/ Can I use a foot switch to make a intercom call?
Q/ CB 600 intercom system not working, can it be repaired
|
A/ There are two systems available the
Pro700, and the
Alphacom.
Both have
Cleanroom Stations
the Pro700 support’s 40 stations and does not have a central exchange, so wiring is very simple,
but the disadvantage is there is only one Speech Channel.
AlphaCom is fully expandable up to 138,000 stations in one location or varies sites globally. There are multiple Speech Channels
|
|
|
A/ speech channels are used to connect stations.
A conversation between two stations uses a speech channel.
If a system has one speech channel (Pro700) and two people are talking, the rest of
the system will be engaged. No other connections can be maid. Except a Emergency Call
which has priority over all other calls except Silent Alarm.
The
Alphacom
system has two speech channels, and the option of adding multiple speech channels.
For every extra subscriber board (6 Station board) added you have an extra speech channel.
|
|
|
A/ The
Alphacom
is best suited for this requirement, a special station has been
designed for this requirement. Please see
Talking Camera System
|
|
|
A/ Both the
Pro700and
Alphacom
can control door entry. You can have a Door
Station at the entry point which can communicate with selected intercom points
during normal hours, and if required connect to specific internal or external location’s
out of hours. The control of the door lock can be controlled from any
of the specified locations.
|
|
|
A/ A Clean Room Station is a station designed for hospital operating theatres,
patient solitary confinements and other clean rooms. The station front foil is made
with Micro ban technology which provides dependable and constant protection against
bacterial contamination.
When bacteria come into contact with the foil, the antimicrobial function disrupts the bacterial cell wall killing or inhibiting bacterial growth. Further more, the station foil is resistant to chemicals and cleaners, and has an excellent scratch resistance.
When flush mounted in the wall and sealed along the rim, there is no risk of fluid
penetration into the station.
|
|
|
A/ A foot switch can be interfaced to most intercom stations in the
Pro700 &
Alphacom range.
The switch is normally a pneumatic type switch which has a pneumatic
to electronic relay. The relay provides a switch contact to open a pre-programmed
voice communication channel.
|
|
|
The CB 600 intercom system is no longer made but we can some times repair it.
We some times have stock of reconditioned CB 600 desk stations if you require a replacement.
The CB 600 was replaced by the Pro700. The
Pro700
looks the same as CB 600 but
the two systems will not work together although you can exchange CB 600 with the Pro700, making use of the same wiring and power supply’s. The CB 600 system is restricted to 16 subscribers, the Pro700 has capacity for 40 stations. The Pro700 Station range is available
here .
|
|
|
|
|
|